Attune CytPix Flow Cytometer

The ATTUNE CYTPIX Flow Cytometer is an advanced cell analyzer that combines acoustic focusing fluidics for high sensitivity and high throughput with a high-speed camera.

Its distinguishing feature is a high-speed brightfield camera that records images of individual events as they pass through the flow cell. The camera and Attune Cytometric Software help to ensure that the events you analyze are single cells as opposed to doublets, clumps, or debris. This is crucial in cell and gene therapy research applications but is useful in almost any flow cytometry experiment to help researchers understand the morphology of each cell population identified for analysis. The images can also aid in identifying debris and optimizing protocols.

Attune-CytPix-Flow-Cytometer

How it works

As samples are acquired on the Attune CytPix Flow Cytometer, the high-speed camera captures and stores images of a sampling of events. For greater flexibility, Attune Cytometric Software lets you adjust the image capture frequency as needed, and can capture up to 6,000 images per second depending on the flow rate and image size. Acoustic focusing helps to position the cells so that a sharp image is obtained.

Acoustic focusing positions cells for optimal imaging

Without acoustic focusing, beads appear off-center and often blurry. Acoustic focusing reduces lateral position variation, temporal variations, and depth of field limitations to obtain a sharp image.

Consistent image quality even at high throughput

Acoustic focusing and a high-speed camera combine to image these CAR T cells consistently at low or high flow rates. Easily adjust focus and camera settings to meet experimental requirements.

Flow-rate-dependent

Optical focus is maintained regardless of the sample flow rate. You can image events at flow rates up to 1,000 µL/minute, and adjust the focus, imaging window, and illumination settings to your target cell type.

Capturing images of cell populations as you acquire flow data lets you select cell images and back gate them on the dot plot or histogram. This allows you to adjust your gates to include cells of interest while excluding aggregates, unwanted cells, and debris. You can combine data from the integrated cell measurement tool with fluorescence and light scatter cytometry to set and confirm gates.

Imaging-enhanced flow cytometry applications

Imaging-enhanced flow cytometer applications include almost any study that can benefit from understanding the morphology of each cell population identified. The imaging capability lets you look more deeply into results to: 

Confirm gate accuracy in real time

Use images to adjust gates and camera settings, and exclude atypical cells and debris for more robust gating

Capture cell-to-cell interactions

With visual clarity

Discover opportunities for analysis

Based on fluorescence, scatter, and morphological features

Further, characterize cell populations

Document morphologically distinct populations in existing protocols such as apoptosis detection

Visualize structural features of large populations

With high-throughput, detailed photographic evidence

High-throughput quality control

Detect quality issues quickly by adding rapid imaging to cell culture QC workflows, and monitor changes in cell morphology as the plate is processed

Confirm gate accuracy

Imaging can be used to confirm and adjust gates to include only single cells of interest. For example, chicken erythrocyte nuclei (CEN) cells are notoriously sticky and tend to clump into doublets or other aggregates. Researchers often identify these aggregates using propidium iodide (PI) assays in which successive peaks correspond to the number of cells in an event. But imaging revealed that next-level aggregates begin to appear on the right shoulders of the preceding peaks. For example, the right shoulder of peak I (assumed to include only singlets) contained many doublets. Tightening the gates enabled the successful removal of the unwanted doublets and shifting them appropriately into the next gate.

Accurate gating for sticky CEN cells.

Original gates (A) contained multiple double events. After evaluating the collected images, it was discovered that these doublets resided on the right shoulder of the singlet peak (B). Gates were adjusted for each peak using the same approach, resulting in an altered gating strategy containing the correct number of events in each peak (C). 

CENs-used-to-test-flow-gating

Characterize cell populations

Morphological information from images can add to the richness of flow cytometry data. For example, the figure shows an otherwise conventional apoptosis assay using Annexin V and PI, adding cell imaging to characterize cells in each population to reveal morphologically distinct features. These insights could not have been gained from multiplex staining alone.

Morphological characteristics of apoptotic cells.

Jurkat cells were incubated with 10 µM camptothecin for 4 hours at 37ºC to induce apoptosis. Samples were stained with Annexin V and PI and acquired on the Attune CytPix Flow Cytometer at 100 µL/minute. From the singlet population, gating strategies identified three cell subpopulations. About 50% of apoptotic live cells (Annexin V+PI–, bottom right) showed some form of the apoptotic body such as blebs. About 25% of apoptotic dead cells (Annexin V+PI+, top right) showed increased cell surface granularity, and there were more partial cells. About 10% of healthy cells (Annexin V, bottom left) showed apoptotic bodies (though not as severe as those observed among Annexin V+ cells). These healthy cells were also morphologically diverse and included some doublets despite upstream singlet gating. Morphological features in the images are indicated by black arrows.

brightfield-imaging-shows-morphology

Cell-to-cell interactions

Imaging can even show interactions between cells. In the figure, engineered CAR T immunotherapy cells were co-incubated with Ramos (lymphoma) cells and stained, acquired, and imaged on the Attune CytPix Flow Cytometer. Images from quadrant Q2 (positive for both stains, acquired as a single event) show the CAR T cells visibly targeting the Ramos cells, clear evidence of engineered cell potency.

Visualization of CAR T cells targeting lymphoma cells.

CAR T and Ramos cells were labeled with CellTrace Far Red and Violet respectively and incubated at a 1:1 ratio for 1 hour at 37°C. Unfiltered samples were acquired on the Attune CytPix Flow Cytometer at 200 µL/minute, >8 x 105 cells/mL. Images of quadrants Q1 (top center), Q4 (bottom right), and Q3 (bottom left) show individual Ramos cells, CAR T cells, and debris, respectively. Images from quadrant Q2 (positive for both stains, top right) reveal both cell types fused together, acquired as a single event as the CAR T cells engulf the Ramos cells.

cell-to-cell-interactions

Discover analysis opportunities

Backgating imaged cells on the Attune CytPix Flow Cytometer also allows you to use morphological features to discover interesting subpopulations that would not be apparent from flow cytometry data alone.

For example, E. coli cells incubated over time develop into two types of colony-forming units (CFUs): short CFUs that resemble single cells, and elongated structures with incomplete fission rings, representing incomplete constriction at each approximate cell length. Neither a traditional singlet gate (SSC-A vs SSC-H) nor a fluorescence gate (SSC vs nucleated stain) sufficiently separates these populations. But with the Attune CytPix imaging-enhanced flow cytometer, you can view and group the images and gate the CFU types based on their morphological characteristics.

Discrimination of two E. coli CFU types.

 E. coli cells were incubated overnight at 37ºC followed by 3 days at 4ºC. Samples were acquired on the Attune CytPix Flow Cytometer at 100 µL/minute. From the images, two types of CFUs were identified: (A) short colonies resembling single cells and (B) elongated structures with incomplete fission rings. Representative images from each population are shown. Backgating on the selected images demonstrated that the two populations are distinct on FSC vs SSC dot plots (orange dots, left).

bacteria-single-CFU
bacteria-elongated-CFU

Cell culture QC

Adding rapid imaging to quality control (QC) workflows can detect and track down cell culture issues early in the process. In one lab, for example, a routine passage check of a Ramos (lymphoma) cell culture observed reduced cell counts and survival despite appearing confluent. Further investigation revealed substantial microbial contamination, but when and where did it begin?

Because the cell line had previously been analyzed on the Attune CytPix Flow Cytometer, the researchers went back to the images and were able to document the microbial infection at least five days earlier. At that time, the early signs were dismissed as debris, but the retrospective evaluation demonstrated shared characteristics with the problematic cells in culture. Tracing the infection helped the lab establish additional laboratory procedures for screening and protection of assay-critical cell lines.

Investigating the contamination of a Ramos cell culture.

Ramos (lymphoma) cells in culture showed reduced cell counts and survival during a routine passage quality check, despite appearing confluent. Further evaluation showed microbial contamination, confirmed by imaging and backgating on the Attune CytPix Flow Cytometer. Early signs of this contamination had initially been dismissed as debris. 

quality-control

Laser and detector configurations

Laser-and-detector-configurations

Request More Info